User Manual

Table Of Contents
General Configuration and Safety
Advanced Digital Motor Controller User Manual 301
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Value
Type: Signed 16-bit
Min: -1000 Max: 1001
Default: 0
Where:
cc : Motor channel
nn : Command value
Example:
^DFC 1 500 : Sets motor command to 500 when no command source are detected
^DFC 2 1001 : Motor takes present position as destination after power up. Motor doesn’t
move.
DMOD – Modbus Mode
HexCode: A1
Description:
Configure this parameter in order to enable Modbus and the desired mode.
Syntax Serial: ^DMOD nn
~DMOD
Syntax Scripting: setconfig(_DMOD, nn)
Number of Arguments: 1
Argument 1: Modbus Mode
Type: Unsigned 8-bit
Min: 0 Max: 4
Default: 0
Where:
nn =
0: Off
1: TCP
2: RTU over TCP
3: RS232 ASCII
4: RS485 ASCII
Example: