User Manual

Table Of Contents
Commands Reference
336 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Default: 120 = 12Volts
Where:
cc = Motor channel
nn = Volts*10
Example:
^BRV 1 200: Sets the Release voltage level of the brake of motor channel 1 to 20Volts.
BHV - Brake Hold Voltage
HexCode: E7
Description:
This parameter is used to select the Voltage level with which the brake solenoid connect-
ed will be hold released. It is applicable only on products that support PWM brake con-
nection. For more details see product’s datasheet. This voltage level is translated in PWM
duty cycle applied on Battery volts. If the value is higher than the battery volts, then the
half value of the battery volts is applied.
Syntax Serial: ^BHV cc nn
~BHV
Syntax Scripting: setconfig(_BHV, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Voltage
Type: Unsigned 16-bit
Min:0 Max: 1000
Default: 80 = 8Volts
Where:
cc = Motor channel
nn = Volts*10
Example:
^BHV 2 50: Sets the Hold Voltage level of the brake of motor channel 2 to 5Volts.