User Manual

Table Of Contents
Motor Configurations
Advanced Digital Motor Controller User Manual 363
~TNM cc
Syntax Scripting: setconfig(_TNM, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Torque Constant Type: Signed 32-bit
Min: 0 Default: 1000 = 1Nm/Amps
Where:
cc = Motor channel
nn = Motor Torque Constant (miliNm/Amps)
Example:
^TNM 1 1523: Set torque constant for motor 1 to 1.523 Nm/Amps.
UVL - Undervoltage Limit
HexCode: 03
Description:
Sets the voltage below which the controller will turn off its power stage. The voltage is
entered as a desired voltage value multiplied by 10. Undervoltage condition is cleared as
soon as voltage rises above the limit.
Syntax Serial: ^UVL nn
~UVL
Syntax Scripting: setconfig(_UVL, nn)
Number of Arguments: 1
Argument 1: Voltage
Type: Unsigned 16-bit
Min: 50 = 5.0V Max: Max Voltage in Product
Datasheet
Default: 50 = 5.0V
Where:
nn = Volts *10
Example:
^UVL 100 : Set undervoltage limit to 10.0 V