User Manual

Table Of Contents
Commands Reference
364 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Brushless Specific Commands
TABLE 15-33. Brushless Specific Commands
Command Arguments Description
BADJ Channel Angle Brushless Angle Zero Adjust
BADV Channel Value Brushless timing angle adjust
BECC Channel Value BEMF Coupling Constant
BFBK Channel Sensor Brushless Sinusoidal Angle Sensor
BHL Channel Value Brushless Internal Sensor Max Limit
BHLA Channel Action Brushless Internal Sensor Action at Max
BHOME Channel Value Brushless Internal Sensor Home Count
BLL Channel Value Brushless Internal Sensor Min Limit
BLLA Channel Action Brushless Internal Sensor Action at Min
BMOD Channel Mode Brushless Switching Mode
BPOL Channel NbrPoles Number of pole pairs
BZPW Channel Amps Brushless Reference Seek Power
HPO InputNbr Value Hall Sensor Position Type
HSAT InputNbr Value Hall Sensor Angle Table
HSM InputNbr Value Hall Sensor Map
KIF PID Channel Gain Current PID Integral Gain
KPF PID Channel Gain Current PID Proportional Gain
LD Channel Value D-axis motor Inductance
LQ Channel Value Q-axis motor Inductance
PSA Channel Angle Phase Shift Angle
RS Channel Value Motor Stator Resistance
SPOL Channel Poles SinCos/SSI Sensor Poles
SSF Channel Frequency Sensorless Start-Up Frequency
SVT Channel Value BEMF Integrator Limit
SWD InputNbr Value Swap Windings
TID Channel Amps FOC Target Id
VK Channel Value Motor Voltage constant
ZSMA Channel Value Cos Amplitude
ZSMC InputNbr Value SinCos Calibration
BADJ - Brushless Angle Zero Adjust
HexCode: 60
Description:
When being in sinusoidal mode and Sin/Cos, Resolver or SSI feedback sensors are used
or in Hall+Encoder Trapezoidal mode, this configuration command stores results of auto-
matic zero degrees angle search after performing the Motor/Sensor Setup (%clmod 2/3).
The angle represents the mechanical offset between the sensor’s zero position and the
rotor’s zero position. The value is in electrical degrees ranging from 0 to 511 for a full elec-
trical turn. The value can then be fine tuned manually.