User Manual

Table Of Contents
Brushless Specific Commands
Advanced Digital Motor Controller User Manual 365
Syntax Serial: ^BADJ cc nn
~BADJ [cc]
Syntax Scripting: setconfig(_BADJ, cc, nn)
Number of Arguments:
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Angle
Type: Signed 16-bit
Min: -511 Max: 511
Default: 0
Where:
cc = Motor channel
nn = Angle
Example:
^BADJ 1 220 : Manually set the zero to 220 degrees
BADV - Brushless timing angle adjust
HexCode: 61
Description:
When operating in sinusoidal mode, this parameter shifts by number of degrees to the 3
phases rotating magnetic field. This value works symetrically to produce the same results
in both rotation direction. The value is in electrical degrees ranging from 0 to 511 for a full
electrical turn.
Syntax Serial: ^BADV cc nn
~BADV [cc]
Syntax Scripting: setconfig(_BADV, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Value
Type: Signed 16-bit
Min: -511 Max: 511
Default: 0
Where:
cc = Motor channel
nn = Angle