User Manual

Table Of Contents
Commands Reference
372 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Number of Pole Pairs
Type: Signed 8-bit
Min: -127 Max: +127
Default: 2
Where:
cc = Motor channel
nn = Number of pole pairs
BZPW - Brushless Reference Seek Power
HexCode: 62
Description:
Sets the level of Amps to be applied to the motor coils during Motor/Sensor Setup. Mo-
tor/Sensor Setup is automatically initiated every time the controller is powered up when
sinusoidal with encoder feedback is selected. Motor/Sensor Setup in necessary to be per-
formed only once in the other cases.
Syntax Serial: ^BZPW cc nn
~BZPW [cc]
Syntax Scripting: setconfig(_BZPW, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Amps
Type: Unsigned 16-bit
Min: 0
Default: 50 = 5.0A
Where:
cc = Motor channel
nn = Amps x 10
HPO - Hall Sensor Position Type
HexCode: A5
Description:
This parameter selects the Hall sensor spacing in the motor. Practically all brushless mo-
tors use Hall sensors with 120 degrees spacing. Some motors have Hall sensors with 60
degrees. Change this parameter only if the motor’s manual clearly specifies 60 degrees
spacing.