Brushless Specific Commands
Advanced Digital Motor Controller User Manual 373
Syntax Serial: ^HPO cc nn
~HPO [cc]
Syntax Scripting: setconfig(_HPO, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Hall Position
Type: Unsigned 8-bit
Min: 0 Max: 1
Default: 0
Where:
cc = Motor channel
nn = Hall Sensor Position
0: 120degree
1: 60degree
Example:
^HPO 1 1: Configure that the Hall Sensor of motor 1 are spaced by 60 degrees.
HSAT - Hall Sensor Angle Table
HexCode: C2
Description:
This parameter is calculated automatically during the motor sensor setup when Hall Sinu-
soidal or Hall+Encoder Sinusoidal is configured. It represents the electrical angle (range
0-512) at each hall transition at each direction.
Syntax Serial: ^HSAT cc nn
~HSAT [cc]
Syntax Scripting: setconfig(_HSAT, cc, nn)
Number of Arguments: 2
Argument 1: Input Value
Min: 1 Max: Total Number of Motors * 12
Argument 2: Electrical Angle