User Manual

Table Of Contents
Brushless Specific Commands
Advanced Digital Motor Controller User Manual 377
Syntax Serial: ^LD cc nn
~LD [cc]
Syntax Scripting: setconfig(_LD, cc, nn)
Number of Arguments: 2
Argument 1: Channel Min: 1 Max: Total Number of Motors
Argument 2: D-axis Motor Inductance
Type: Unsigned 16-bit
Min: 0 Max: 65535
Default: 0
Where:
cc = Motor channel
nn = D-axis motor inductance in Henry * 1,000,000
Example:
^LD 1 750 : Set the d-axis motor inductance to 0,000750 H = 750 uH
LQ - Motor q-axis Inductance
HexCode: ED
Description:
Set the q-axis motor inductance. This configuration command is necessary for IPM motor
operation. If value is set to 0 then the motor operates as brushless dc motor with Id refer-
ence command set, by default, to 0.
Syntax Serial: ^LQ cc nn
~LQ [cc]
Syntax Scripting: setconfig(_LQ, cc, nn)
Number of Arguments: 2
Argument 1: Channel Min: 1 Max: Total Number of Motors
Argument 2: Q-axis Motor Inductance
Type: Unsigned 16-bit