User Manual

Table Of Contents
Commands Reference
378 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Min: 0 Max: 65535
Default: 0
Where:
cc = Motor channel
nn = Q-axis motor inductance in Henry * 1,000,000
Example:
^LQ 1 950 : Set the q-axis motor inductance to 0,000950 H = 950 uH
PSA - Phase Shift Angle
HexCode: E1
Description:
When being in sinusoidal mode and Sin/Cos or Resolver feedback sensors are used,
this configuration command defines the Phase Shift Angle between the Sin and Cos sig-
nals. The value is in degrees ranging from 0 to 511. If the sensor is a regular Sin/Cos or
Resolver Sin/Cos sensor, the phase shift angle is 90
o
degrees, so we need to configure
90*512/360 = 128. If not then the sensor manufacturer should inform about the phase
shift angle.
Syntax Serial: ^PSA cc nn
~PSA [cc]
Syntax Scripting: setconfig(_PSA, cc, nn)
Number of Arguments:
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Angle
Type: Signed 16-bit
Min: -511 Max: 511
Default: 128
Where:
cc = Motor channel
nn = Angle
Example:
^PSA 1 171 : Set the phase shift angle to 171*360/512 = 120
o