User Manual

Table Of Contents
Brushless Specific Commands
Advanced Digital Motor Controller User Manual 383
Syntax Scripting: setconfig(_TID, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Amps
Type: Signed 32-bit
Min: 0
Default: 0
Where:
cc = Motor Channel
nn = Amps * 10
VK - Motor Voltage constant
HexCode: EE
Description:
Set the motor voltage constant. This parameter is necessary for IPM motor operation. This
constant considers the peak amplitude of induced phase to phase motor back-emf per
1000 rpm mechanical speed. It is typically included in motor manufacturer’s datasheet.
Syntax Serial: ^VK cc nn
~VK [cc]
Syntax Scripting: setconfig(_VK, cc, nn)
Number of Arguments: 2
Argument 1: Channel Min: 1 Max: Total Number of Motors
Argument 2: Motor voltage constant
Type: Unsigned 32-bit
Min: 0 Max: 2000000
Default: 0
Where:
cc = Motor channel
nn = Motor voltage constant in V/krpm * 1000