User Manual

Table Of Contents
Brushless Specific Commands
Advanced Digital Motor Controller User Manual 389
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Minimum Power
Type: Unsigned 16-bit
Min: 0 Max: 1000
Default: 100
Where:
cc = Motor channel
nn = Motor’s Minimum Power in % of PWM Level
Example:
^MPW 1 200: Set Minimum Power for motor 1 to value 20.0% PWM Level.
MXS - Optimal Slip Frequency
HexCode: 96
Description:
This parameter is only used for AC Induction controllers. The optimal slip is the value that
the controller will work to maintain while operating in Constant Slip mode.
Syntax Serial: ^MXS cc nn
~MXS [cc]
Syntax Scripting: setconfig(_MXS, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: Optimal Slip Frequency
Type: Unsigned 16-bit
Min: 0 Max: 65535
Default: 50