User Manual

Table Of Contents
CAN Communication Commands
Advanced Digital Motor Controller User Manual 391
Syntax Serial: ^VPH cc nn
~VPH [cc]
Syntax Scripting: setconfig(_VPH, cc, nn)
Number of Arguments: 2
Argument 1: Channel
Min: 1 Max: Total Number of Motors
Argument 2: VoltsPerHz
Type: Unsigned 16-bit
Min: 0 Max: 65535
Default: 20000
Where:
cc = Motor channel
nn = Motor’s Volts per Hertz * 1000
Example:
^VPH 1 200: Set Volts per Hertx to value 0.200
CAN Communication Commands
This section describes all the configuration parameters uses for CANbus operation.
TABLE 15-36. CANbus Commands
Command Arguments Description
CAS Rate CANOpen Auto start
CBR BitRate CAN Bit Rate
CEN Mode CAN Mode
CHB HeartBeat CAN Heartbeat
CHLA Action CAN Consumer Heartbeat Lost Action
CLSN Address CAN Listen Node ID
CNOD Address CAN Node ID
CSRT Rate MiniCAN SendRate
CTPS TPDOnbr Rate CANOpen TPDO SendRate
CTT None CANOpen Transmission Type
FSA None DS402 FSA