User Manual

Table Of Contents
Commands Reference
398 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
ler to access the network. By enabling DHCP service, the controller uses the IP address
provided by the DHCP server.
Syntax Serial: ^DHCP nn
~ DHCP
Syntax Scripting: setconfig(_DHCP, nn)
Number of Arguments: 1
Argument 1: Enable DHCP
Type: Unsigned 8-bit
Min: 0 Max: 1
Default: 0
Where:
nn = Enable DHCP
0: Disabled.
1: Enabled.
Example:
^DHCP 1: Enable DHCP.
GWA - Gateway Address
HexCode: 69
Description:
Configure this parameter in order to set the Gateway Address of your controller’s net-
work. Gateway Address option includes 4 values representing each octet in the IP ad-
dress v4 format. The default Gateway Address value is 192.168.1.1.
Syntax Serial: ^GWA cc nn
~GWA
Syntax Scripting: setconfig(_GWA, cc, nn)
Number of Arguments: 2
Argument 1: IP Octet
Type: Unsigned 8-bit
Min: 1 Max: 4
Argument 2: Gateway Address
Type: Unsigned 8-bit
Min: 0 Max: 255
Default: