User Manual

Table Of Contents
Motor Operating Features and Options
96 Advanced Digital Motor Controller User Manual V2.1, December 3, 2020
Below is the description of the parameters illustrated in Figure 7-11.
P* = position reference command value, in counts at count position and speed position
modes and in -1000/1000 command at tracking position and position relative modes
P = measured position from motor sensor, in counts at count position and speed position
modes and in -1000/1000 command at tracking position and position relative modes
P
n
= position reference command value every msec, calculated from trajectory function
according to configured acceleration, deceleration and speed
S* = speed reference command value in rpm
S = measured motor mechanical speed in rpm
I
s
* = reference current command value in Ampere
I
q
* = q-axis reference current command value in Ampere (Torque Amps command)
I
d
* = d-axis reference current command value in Ampere (Flux Amps command)
I
q
* = q-axis current measurement in Ampere (Torque Amps)
I
d
* = d-axis current measurement in Ampere (Flux Amps)
V
q
* = q-axis reference voltage command Volts
V
d
* = d-axis reference voltage command in Volts
V
abc
* = reference instantaneous applied 3-phase voltage command at mosfet bridge in Volts
I
a
= measured motor phase A instantaneous current
I
b
= measured motor phase B instantaneous current
θ
e
= measured motor electric angle