User's Manual

Electrical Performance of Intellibox
Testing conditions
5.4.1 The ambient temperature ranges from - 20 to 60.
5.4.2 Operating voltage: 100-240VAC;
5.4.3 Accessories: Power Meter, Multimeter, Remote Controller, OCS
RFID Casters and Oscilloscopes
5.4.4 Test methods:
1.Power-on debugging: connect Intellibox to power meter
and 220VAC, and adjust the output of internal switching power supply
13V after power-on.
2. LOOP A debugging and testing: LOOP A connects 2.2 ohm
load, adjusts A signal to level 9, oscilloscope clamp connects both
ends of load, debugs sinusoidal wave, adjusts frequency to 8.13KHz, P-
P value to 3 V±5%; OCS RFID casters will lock when they receive two A
signals.
3. LOOP C debugging and testing: LOOP C connects 2.2 ohm
load, adjusts C signal to level 9, oscilloscope clamp connects both
ends of load, debugs sinusoidal wave, frequency is 8.13KHz, P-P value
is 3 V±5%; OCS RFID casters initialize the program after receiving C
signal, and do not lock after receiving A signal.
4. LOOP H debugging and testing: LOOP H connects 2.2 ohm
load, adjusts H signal to level 9, oscilloscope clamp connects both
ends of load, debugs sinusoidal wave, frequency is 8.13KHz, P-P value
is 3 V±5%; OCS RFID casters receive C signal and A signal after 30
seconds, receive B signal after 10 seconds and receive A signal without
No. ITEM Parameters Others
Normal
temperature
Environmental
Tests - 20-60
Over/Low
voltage test
1
working
voltage
100-240VAC 100-240VAC 100-240VAC
2 LOOP A PP
value (level 9)
3V ±5% 3V ± 5% 3V ±5%
3 LOOP C PP
value (level 9)
3V± 5% 3V ±5% 3V ±5%
4 LOOP H PP
value (level 9)
3V ±5% 3V ± 5% 3V ±5%
5
Transmitting
frequency
(A/C/H)
8.13KHz
6
Receiving
frequency
2.4GHz