User's Manual

locking; receive B signal and receive A signal within 10 seconds. Then
lock.
5.Power test: LOOP A/C/H is connected with 2.2 ohm load, the
A/C/H signal is adjusted to level 9, the power of input power meter is
less than 20W.
6.Alarm function test: Intellibox receives 2.4 GHz alarm
signal through antenna, sends 2.4 GHz alarm signal with special remote
controller, or receives two AA signals locked and 2.4 GHz alarm signal
with OCS RFID casters. Intellibox alarms after receiving the signal,
silences after receiving the remote control muffling signal, the
receiving distance is more than 10 meters.
7.Reset button test after 24 hours: 24 hours after the
Intellibox is turned on, the remote control can not be set. The reset
button can be set by remote control only after pressing the reset
button.
5. Inspection Rules
5.1.1 Exit Inspection Contents See 5.1-5.4
5.1.2 Exit inspection shall be carried out batch by batch according
to ANSI/ASQZ1.4-2003.
5.2 type inspection
5.2.1 When Intellibox has one of the following conditions, it should be type
checked:
A. Trial-formulation type identification of new or old products
transferred to factories;
B. When the design, process and material of the product have changed
significantly;
C. When production is suspended for more than eight months and put
into operation again;
D. Normally continuous production of products, once a year;
E. When the State Quality Supervision Authority puts forward the
requirements for type inspection.
5.2.2 When any item of Intellibox in type inspection is not
qualified, double sampling should be taken from the same batch of
products and the unqualified items should be re-examined .If any item
in the reexamination is not qualified, the batch of products will not
be qualified .Unqualified products shall be re-submitted for testing
after improvement or repairs.
5.3 Check before acceptance
The orderer accepts the products according to the ex-factory
inspection items. In case of quality disputes, both the supplier and
the demander review the products according to the supply agreement.