User Manual

The fog machine must be used in a horizontal position on a level surface or it may be
mounted using the bracket provided. Whatever method of installation you choose, the
fog machine must not have more than a 15 degree angle of inclination. We always sug-
gest that for safety purpose use of a suitable hanging clamp and safety cable is essential.
Do not allow fog uid to become contaminated. Always replace cap after use.
There are no user serviceable parts in this unit. Any work on internal parts should be
carried out by a qualied technician. Removal of any covers is considered a breach of
warranty.
If you experience low output, pump noise or no output at all, unplug immediately. Check
uid level, check the hose attached to the tank and make sure there are no obstruc-
tions and uid is owing through the hose, check the external fuse, remote connection,
and main power supply. Ensure that tank is lled and all other components are working
properly. If all appear to be OK, plug the unit in again. If the unit still does not operate
properly and you are unable to determine the cause of the problem, contact Rockville for
servicing.
ATTENTION: If the unit is unable to produce fog, do not continue to push the remote
control button as this may cause permanent damage.
Cleaning your fog machine regularly will help reduce costly parts replacement and repair
charges. We recommend you clean your fog machine after every 40 hours of continues
operation or when the machine will be idle for a long time. Run a cleaning solution com-
posed of 80% distilled water and 20% white vinegar through the system to prevent the
accumulation of particles in the heating element.
1. While unit is unplugged and cool, unscrew nozzle at very front of unit and clean out
debris with white vinegar and a pipe cleaner, making sure that the hole is unobstructed.
2. Empty all fog uid from the machine and replace with cleaning solution. Plug the unit in
and allow to heat up as usual.
3. Run unit in a well ventilated area until tank is empty.
4. Replace nozzle.
5. Cleaning is now complete. Unplug and wait until it is cool before relling with Rockville
fog uid or any other water based fog uid.
6. To clean the exterior, wipe with a dry cloth.
7. Always store the unit dry (no uid in the tank).
All fog machines are prone to clogging due to the consistency of uids and the high
temperatures at which they vaporize. However, a well maintained machine should provide
years of reliable use.
Installation/Mounting
Maintenance/Servicing
Troubleshooting
Cleaning