Owner manual

Publication 1326A-IN024B-EN-P - May 2007
2 Right-angle Connection for Series B 1326 Cables
Connector Dimensions
This table lists dimensions for the 1326-xxx-RAL-xxx and 1326-xxx-RBL-xxx
connectors.
Cable Bend Radius
The table and diagram depict the minimum bend radius for cables. Bend
radius is the tightest (minimum) curvature allowed without potential damage
to the cable.
Cable Height, Approx.
mm (in.)
Diameter,
Approx.
mm (in.)
Diameter at Bellows,
Approx.
mm (in.)
1326-CCUT-RAL-xxx, 1326-CCUT-RBL-xxx
66.80 (2.63) 40.38 (1.59) 38.61 (1.52)
1326-CECUT-RAL-xxx, 1326-CECUT-RBL-xxx
66.80 (2.63) 40.38 (1.59) 38.61 (1.52)
1326-CPB1T-RAL-xxx, 1326-CPB1T-RBL-xxx
69.85 (2.75) 46.99 (1.85) 45.47 (1.79)
1326-CPC1T-RAL-xxx, 1326-CPC1T-RBL-xxx
84.07 (3.31) 57.15 (2.25) 55.37 (2.18)
htHeight
Diameter
Heig
htHeight
Diameter
Diameter
at bellows
1326-xxx-RA-xxx
and 1326-xxx-RB-xxx
1326-xxx-RAL-xxx
and 1326-xxx-RBL-xxx
Dimensions for the
1326-xxx-RAL-xxx and
1326-
xxx-RBL-xxx
Connectors
Motor Power Cable
Catalog Number
1326-CCUT-xxx 1326-CECUT-xxx 1326-CPB1T-xxx 1326-CPC1T-xxx
Bend Radius Diagram
BR, Approx
(1)
mm (in.)
50.8 (2.0) 120 (4.7) 104.1 (4.1) 160.2 (6.3)
(1)
Bend radius (BR) is the specified minimum bend radius for cable assemblies. For non-flex cables, BR is a one-time flex application. Flex cables have a much higher BR to
withstand flex applications. The BR for user-fabricated cables may vary.
BR
Bend Radius