User Manual
4–79Using Unscheduled Messaging
Publication 1336 FORCE–5.18 ––March, 1999
The offset specifies where in the buffer you want to start reading the
32 data points. For example, if you specify an offset of 64, the Run
File Data function returns the 32 data samples starting from data
sample 64.
If you request less than 32 trend samples, then the file data is padded
with zeros. If you request data samples past the end of the buffer,
then the file data is padded with zeros.
This data is read from the triggered trend file. Once the buffer is
filled based on the post sample number, no more data is stored and
the file does not change.
Example