User Manual
6–25Parameters
Publication 1336 FORCE–5.18 ––March, 1999
376
Flux Owner
[Flux Owner]
Flux Owner displays which ports are presently
issuing a valid Flux Enable command.
Parameter Number 376
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
377
Trim Owner
[T rim Owner]
Trim Owner displays which port is presently issuing
a Trim Enable command.
Parameter Number 377
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
378
Ramp Owner
[Ramp Owner]
Ramp Owner displays which port is presently issuing
a Ramp command.
Parameter Number 378
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
379
Clear Fault Owner
[Clr Fault Owner]
Clr Fault Owner displays which port is presently
issuing a Clear Fault command.
Parameter Number 379
Parameter Type Read Only, Source
Display Units / Drive Units Bits
Factory Default 0
Minimum Value 0
Maximum Value 0FE Hex
File – Group Communications I/O – SCANport Owners
Enums Bit 1 = Port 1 Bit 2 = Port 2 Bit 3 = Port 3 Bit 4 = Port 4
Bit 5 = Port 5 Bit 6 = Channel A Bit 7 = Channel B
386
SCANport Analog Output
[SP Analog Out]
SP Analog Out passes the value it contains to the
attached SCANport devices. For example, you can
link one of the output parameters to SP Analog Out
and each of the five SCANport devices could read
the value of the output parameter.
Parameter Number 386
Parameter Type Read/Write, Sink
Display Units / Drive Units ±32767
Factory Default 0
Minimum Value –32767
Maximum Value +32767
File – Group Communications I/O – Analog Output