User Manual

1–7Installing and Wiring Your ControlNet Adapter Board
Publication 1336 FORCE–5.18 ––March, 1999
The typical analog input connections for bidirectional operation can
be shown as follows:
COM (POWER SUPPLY COMMON)
IN + (ANALOG IN)
+ 10V
DC (POWER SUPPLY)
IN – (ANALOG IN)
18
REFERENCE POT
2.5 k MINIMUM
TB21
17
– 10V
DC (POWER SUPPLY)
19
ADC
REVERSE
FORWARD
R
Reverse
Reverse
Relay
Forward
TO TE
(SIGNAL GROUND TERMINAL BLOCK)
Note: Connect to Only One Set of Inputs
IN4+ and IN4–
IN3+ and IN3–
IN2+ and IN2–
IN1+ and IN1–
The following table shows the analog input specifications:
Specifications:
Value:
Differential impedance Greater than 1 Ohm
Single ended impedance 20K Ohm
Maximum voltage
±10V
Analog Outputs
The ControlNet Adapter Board has 4 analog outputs that have a
range of ±10V and a digital resolution of 12 bits. Chapter 2, Starting
Up, describes the parameters associated with scaling analog values.
The typical analog output connections can be shown as follows:
OUT (ANALOG OUT)
COM (ANALOG OUT)
TB21
DAC
0 to ±10V
DC
1mA Maximum
100 Ohm
Maximum Impedance
TO TE
(SIGNAL GROUND TERMINAL BLOCK)
Note: Connect to Only One Set of Outputs
COM4 and OUT4
COM3 and OUT3
COM2 and OUT2
COM1 and OUT1