Manual
Serial Port Parameters
Firmware Version 1.01-3.01
Chapter 4
4-2
Parameter 54 Local Input Read Only
Units Byte
Min V
alue 0
Max Value 255
This parameter is an eight-bit word that reports the status of the
pushbuttons on an optional Control or Programming and Display Panel.
BIT 1
Start
Jog
Stop
Enter
P
R
BIT 0
BIT 2
BIT 3
BIT 4
BIT 5
BIT 6
BIT 7
0 = Off (not pressed) 1 = On (pressed)
Parameter 55 Remote Input Read Only
Units Byte
Min V
alue 0
Max Value 255
This parameter is an eight-bit word. Each bit represents the status of the
customer connection to remote terminal block TB3.
BIT 0 — TERM 27 — Select speed
BIT 1 — TERM 28 — Auxiliary
BIT 2 — TERM 26 — SW2
BIT 3 — TERM 24 — SW1
BIT 4 — TERM 22 — Jog
BIT 5 — TERM 23 — Reverse
BIT 6 — TERM 20 — (not) Stop
BIT 7 — TERM 19 — Start
0 = Off (not present) 1 = On (present)