Manual
Local and Serial Port Parameter Settings
Firmware Version 1.01-3.01
Chapter 9
9-2
Table
9 -- Parameter List for Parameters 0 to 50 (cont.)
Local
Programming Serial
Panel Port
Parameter Parameter Min/Max Min/Max Factory
Number Text Units Values Values Setting
30 ACCEL TIME 2 Seconds 0/600 0.00/600.00 5
31
DECEL TIME 2
Seconds 0/600 0.00/600.00 5
32
SKIP FREQUENCY 1
Hertz 0/250 0/250 250
33
SKIP FREQUENCY 2
Hertz 0/250 0/250 250
34
SKIP FREQUENCY 3
Hertz 0/250 0/250 250
35
SKIP FREQUENCY BAND
Hertz 0/15 0/15 0
36 MOPC
% of Rated Output Current
50/115 50/115 115
37
SERIAL BAUD RA
TE Code 0/1 0/1 1
38
OVERLOAD CURRENT
% of Rated Output Current
50/115 50/115 100
39 FAUL
T CLEAR
Off/On 0/1 0/1 1
40 POWER FAULT Off/On 0/1 0/1 0
41 MOTOR TYPE Code 0/2 0/2 0
42
SLIP COMPENSA
TION Hertz .0/5.0 0.00/5.00 .0
43
DWELL FREQUENCY
Hertz 0/120 0/120 0
44
DWELL TIME
Seconds 0/10 0/10 0
45
PWM FREQUENCY
kHZ .40/2.00 0.40/2.00 .40
46
PULSE SCALE F
ACTOR Ratio 1/255 1/255 64
47 LANGUAGE Code 0/5 0/5 0
48 START BOOST Volts 0/115 0/115 0
49 BREAK FREQ Hertz 0/120 0/120 0
50
BREAK VOL