Instruction Sheet User guide
General Operation 4-27
1403-IN001A-US-P
Min/Max Log
The Min/Max log records the minimum and
maximum values for 84 parameters. These
parameters are listed in Table 4.15. The parameter
values are continuously monitored until the Min/Max
log is cleared or when the log is disabled. The Min/
Max log can be disabled to make the real time
metering update approximately 10 ms faster.
The Min/Max log can be displayed using the Display
Module or via the Smart Communication Card. The
Display Module individually displays the minimum
and maximum values for each of the 84 parameters.
The date and time at which a specific minimum and
maximum value occurs is displayed by pressing
Enter (
↵
) at the appropriate parameter.
Table 4.15 The Parameter Listing for the Min/Max Log
Parameter Number Parameter Description
1 Phase 1 Current
2 Phase 2 Current
3 Phase 3 Current
4 Phase 4 Current
5 Average Current
6 Positive Sequence Current
7 Negative Sequence Current
8 Current Unbalance
9 Phase 1 L-L Voltage
10 Phase 2 L-L Voltage
11 Phase 3 L-L Voltage
12 Auxiliary Voltage
13 Average L-L Voltage
14 Positive Sequence Voltage
15 Negative Sequence Voltage
16 Voltage Unbalance
17 Phase 1 L-N Voltage
18 Phase 2 L-N Voltage
19 Phase 3 L-N Voltage
20 Average L-N Voltage
21 Frequency
22 Phase 1 Real Power
23 Phase 2 Real Power
24 Phase 3 Real Power
25 Total Real Power
26 Phase 1 Reactive Power
27 Phase 2 Reactive Power
28 Phase 3 Reactive Power
29 Total Reactive Power
30 Phase 1 Apparent Power
31 Phase 2 Apparent Power
32 Phase 3 Apparent Power
33 Total Apparent Power
34 Phase 1 True Power Factor
35 Phase 2 True Power Factor
36 Phase 3 True Power Factor
37 Total True Power Factor
38 Phase 1 Displacement Power
Factor
39 Phase 2 Displacement Power
Factor
40 Phase 3 Displacement Power
Factor
41 Total Displacement Power Factor
42 Phase 1 Distortion Power Factor
43 Phase 2 Distortion Power Factor
44 Phase 3 Distortion Power Factor
45 Total Distortion Power Factor
46 Current Demand
47 Real Power Demand
48 Reactive Power Demand
49 Apparent Power Demand
50 Phase 1 Voltage IEEE THD
51 Phase 1 Voltage IEC THD
52
(1)
Phase 1 Voltage TIF
53
(1)
Phase 1 Voltage Crest Factor
54
(1)
Phase 1 Voltage K-factor
55 Phase 1 Current IEEE THD
56 Phase 1 Current IEC THD
57
(1)
Phase 1 Current TIF
58
(1)
Phase 1 Current Crest Factor
59
(1)
Phase 1 Current K-factor
60 Phase 2 Voltage IEEE THD
61 Phase 2 Voltage IEC THD
62
(1)
Phase 2 Voltage TIF
63
(1)
Phase 2 Voltage Crest Factor
64
(1)
Phase 2 Voltage K-factor
65 Phase 2 Current IEEE THD
66 Phase 2 Current IEC THD
67
(1)
Phase 2 Current TIF
68
(1)
Phase 2 Current Crest Factor
Table 4.15 The Parameter Listing for the Min/Max Log