Owner manual

Publication GMSI10-UM004B-EN-P - May 2010
Installing the XM-220 Dual Speed Module 35
Sensor Placement for Reverse Rotation
The XM-220 module uses two input signals for reverse rotation detection.
Connect the first sensor to Channel 1. Connect the second sensor to Channel
2. Refer to Connecting a Non-Contact Sensor on page 30 for wiring details.
Position the sensors so that:
The keyway passes Channel 1 sensor before it passes Channel 2 sensor
as the machine rotates in the forward direction, as illustrated in
Figure 2.25.
Figure 2.25 Position of the Sensor
The sensors are more than 10 degrees apart and less than 170 degrees
apart in the direction of forward rotation; 90 degrees is optimum. See
Figure 2.26.
KEY (OR SLOT)
ON SHAFT
DIRECTION
OF ROTATION
CHANNEL 1 SENSOR
CHANNEL 2 SENSOR