User Manual User Manual

9-4 Troubleshooting
Prestart fault indication.
Table 9.B Motor Will Not Start — No Output Voltage to the Motor
Table 9.C Motor Rotates (but does not accelerate to full speed)
V24 Recovery F44 Control module internal 24V control
power stays low after closing bypass
contactor
Check control power. Make sure it is within the
operating parameters of the SMC
Check control power connections, including ground,
to the control module
Replace control module
V24 Loss F45 Control module internal 24V supply
out of normal range
Same as F44
V Control F46 Sense of control voltage in error Same as F44
Option Input 1, 2 F48, F49 Fault occurs based on the user
configuration of the option input
Review the option input fault configuration and clear
the fault condition
Varies (control module
system faults)
F128-F209 Control module wiring
Control module defective
Review the control module wiring. Ensure ground
terminal is secure connected to system earth
ground. Ensure an RC snubber is connected to all
inductive loads in the control circuit (refer to input
wiring)
Replace the control module
Table 9.A SMC Fault Display Explanation (Continued)
Display Fault Code Possible Causes Possible Solutions
Display Possible Cause Possible Solutions
Fault displayed See fault description See Table 9.A addressing
fault conditions
Display is blank Control voltage is
absent
Failed control module
Check control wiring and
correct if necessary
Replace control module
Cycle control power
Stopped
0.0 Amps
Pilot devices
SMC Enable input is
open at terminal 13
Input terminals are not
wired correctly
Start-Stop control has
not been enabled for
the human interface
module
Control voltage
Failed control module
•Check wiring
•Check wiring
•Check wiring
Follow the instructions on
page 7-4…7-6 to enable
control capability
Check control voltage
Replace control module
Starting Two or three power
phases are missing
Check power system
Display Possible Cause Possible Solutions
Fault displayed See fault description See Table 9.A addressing
fault conditions