3-32 Wiring
Figure 3.30 Preset Slow Speed Sequence of Operation
S
tar
t
R
un
1
00%
M
o
t
or
S
p
ee
d
Time
(
seconds
)
U
p
-to-s
p
ee
d
Auxiliar
y
Contact
s
P
us
h B
u
tton
s
Norm
al
Slow S
p
ee
d
Sto
p
S
tar
t
C
lose
d
C
lose
d
O
p
e
n
C
lose
d
O
p
e
n
C
lose
d
O
p
e
n
O
p
e
n
C
lose
d
O
p
e
n
7 or 1
5%
C
oas
t
Slow S
p
ee
d
C
oast-to-res
t
Soft Sto