Figure 2.8 Count Range with Ring Counter
Range
Start
Value
Stop
Value
Outputs
(1)
(1) Bits 0 through 3 are real outputs. Bits 4 through 7 are virtual outputs.
Outputs
Affected
76543210
1 10,000 12,500 0 0 0 0 0 0 0 1 0
2 200 8,000 00000010 1
3 32,000 500 0 0 0 0 0 1 0 0 2
4 20,000 23,000 0 0 0 0 1 0 0 1 0 and 3
1
32,767
32,000
200
500
8,000
10,000
12,500
20,000
23,000
Range 3
Range 2
Range 4
Range 1