INSTALL INSTRUC MOLD PRESSURE Manual
6 Mold Pressure Module
(
Scaled data transferred from the module
Bit commands to the module Bit status from the module
00 trigger 1, start machine cycle 00 channel 1 alarm
01 trigger 2, injection fill time 01 channel 2 alarm
02 trigger 3, screw backup time 02 cycle time alarm
03 trigger 4, mold closed time 03 channel 1 loss of sensor
04 set channel 1 zero offset 04 channel 2 loss of sensor
05 set channel 2 zero offset 05-07 spare
06 shunt calibration bit - Never set
concurrently with bit 04 or 05
08 trigger 1 is ON
09 reading chnl 1 zero offset
07-15 reserved 10 reading chnl 2 zero offset
11 reading redundant permissive
12-15 reserved
PSI
Counts
π
D
2
2
9vdc
L
× x
4095xCounts
10vdc
=
Where:
D = diameter of the ejector pin
L = full-load rating of the sensor
PSI
Counts L×
D
2
2894.58×
=
PSI
Counts
π
D
2
2
10vdc
L
× x
4095xCounts
10vdc
=
PSI
Counts L×
D
2
3612.2×
=
Important:
For a sensor with 20mA full-load output,
use this same computation.