INSTALL INSTRUC MOLD PRESSURE Manual

Mold Pressure Module 9
%
Bit Purpose Selection
00-02 reserved n/a
03 Chnl 1 source of data 0 = sensor, 1 = SLC output image table
04 Chnl 2 source of data 0 = sensor, 1 = SLC output image table
05-08 reserved n/a
09 Trigger Operation 0 = triggers, 1 = no triggers
10 channel 1 & 2 alarms turned off by T4 0 = no, 1 = yes
11 Channel 1 & 2 alarms go OFF when T4
(mold closed) trigger does the following:
0 = goes ON (at mold close),
1 = goes OFF (at mold open)
12 Channel 1 sensor level 0 = high, 1 = low (must match jumpers)
13 Channel 2 sensor level 0 = high, 1 = low (must match jumpers)
14 Alarm operation 0 = alarms, 1 = no alarms
15 module reset 1 = set (required)
F200
Senser level = high for both channels, and alarms = off
(bits 15-12 = 1 1 1 1 = F)
Triggers and T4 = off (bits 11-08 = 0 0 1 0 = 2)
Data source = from sensors for both channels (bits 07-00 = 0)
0 4040000
5 00000
10 00000
: :::::
90 00000