Manual
Publication 1756-UM522B-EN-P - February 2003
B-36 1756-DMD30 Speciļ¬c Information
103 Spd Reg Neg Lim
The negative limit of the Speed regulator output value. The
output of the Speed regulator is limited by adjustable high and
low limits.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
-3
-6
0
Linkable, Read-Write, Floating Point
Speed Control
Regulator
108 Spd Reg TP Sel
Enter or write a value to select speed regulator data displayed
in parameter 109 [Spd Reg TP Data].
Default: Val 0 Zero
Options: Val 0
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Val 7
Val 8
Val 9
Val 10
Val 11
Val 12
Val 13
Val 14
Val 15
Val 16
Val 17
Val 18
Val 19
Zero
Spd FiltOut
Servo Lock
Spd+ServLock
Prop Output
Intg Input
Scld Int Pre
Sel Int Pre
Droop Output
Out Lim Stat
Intg Hold
ReservedI
GainParLim
P GainParLim
SrvLck ParLm
AntiBkup PLm
Droop ParLim
Pos Lim Stat
Neg Lim Stat
Limiter Out
File:
Group:
Utility
Test Points
109 Spd Reg TP Data
Displays the data selected by parameter 108 [Spd Reg TP Sel].
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Non-Linkable, Read Only, Floating Point
Utility
Test Points
110 Spd/Torq ModeSel
Selects the source for the drive torque reference. It operates
as a selector switch, whose position determines the torque
reference selection.
Default: Val 1 Speed Reg
Options: Val 0
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Zero Torque
Speed Reg
Torque Ref
Min Spd/Torq
Max Spd/Torq
Sum Spd/Torq
AbsMn Spd/Tq
File:
Group:
Torque Control
Torque
No. Name
Description
Values