111 Torque Ref 1
Supplies an external motor torque reference to the drive. This
parameter is divided by the value inparameter 112 [Torq Ref1
Div]. A value of 1.0 represents rated torque of the motor.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Torque Control
Torque
112 Torq Ref1 Div
The divisor for parameter 111 [Torque Ref 1].
Default:
Min:
Max:
Type:
File:
Group:
1
-2200000000
2200000000
Non-Linkable, Read-Write, Floating Point
Torque Control
Torque
113 Torque Ref 2
Supplies an external motor torque reference to the drive. This
parameter is multiplied by the value in [Torq Ref2 Mult]. A
value of 1.0 represents rated torque of the motor.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Torque Control
Torque
114 Torq Ref2 Mult
The multiplier for parameter 113 [Torque Ref 2].
Default:
Min:
Max:
Type:
File:
Group:
1
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Torque Control
Torque
115 Torque Trim
The amount added to the Torque Reference before the Speed -
Torque Mode Selector. A value of 1.0 represents rated torque
of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Linkable, Read-Write, Floating Point
Torque Control
Torque
116 Torque Step
The amount added to the selected Torque Reference before
notch filtering or limits are applied. A value of 1.0 represents
rated torque of the motor.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Linkable, Read-Write, Floating Point
Torque Control
Torque
117 Notch Filt Mode
Enter or write a value to select the type of notch filter.
Default: Val 0 No Filter
Options: Val 0
Val 1
Val 2
No Filter
FIR NotchI
IR Notch
File:
Group:
Torque Control
Torque
No. Name
Description
Values