Manual
Publication 1756-UM522B-EN-P - February 2003
B-8 1756-DMD30 Speciļ¬c Information
Position Control - Auxiliary
Latch
Latch
Latch788
790
793
Sync Generator
787
789
791
792
794
795
317
0.5ms
Position Watch 1
Position Watch 2
In Position Detect
763
740 16
740 17
780
741 08
741 09763
740 18
740 19
781
769
782
783
741 10
Xsync In 1 Xsync Out 1
Xsync Out 2
Xsync In 2
Xsync In 3
Xsync Out 2 Dly
Xsync Out 3 Dly
Xsync Out 3
Xsync Gen Period
SL System Time
Xsync Status
(Sync Pulse)
Sync Pulse Generator
0.5ms * 2
(p787)
0.5ms
786 00
Act Motor Posit
Act Motor Posit
Position Control
(X Watch 1 En)
(X Watch 1 Dir)
Position Control
(X Watch 2 En)
(X Watch 2 Dir)
PositDtct1 Stpt
PositDtct2 Stpt
In Posit BW
InPosit Dwell
Position Error
Position Status
(Posit Watch1)
Position Status
(Posit Watch2)
Position Status
(In Position)
Position Control (4 ms)
Auxiliary
Delay
One
Scan
Delay
One
Scan
1
2
3
4
5
6
BA
D
C
FE HG I