Instruction Manual
Table Of Contents
- 1769-UM006E-EN-P, Compact High-speed Counter Module User Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Module Overview
- 2 - Module Operation
- 3 - Installation and Wiring
- 4 - Module Configuration, Output, and Input Data
- Configure the Module
- Configuration Array
- General Configuration Bits
- Filter Selection
- Program Mode and Program State Run
- Output Program Value (Out0ProgramValue through Out3ProgramValue)
- Output Fault Mode and Output Fault State Run
- Output Fault Value (Out0FaultValue through Out3FaultValue)
- Counter Maximum Count (CtrnMaxCount)
- Counter Minimum Count (CtrnMinCount)
- Counter Preset (CtrnPreset)
- Counter Hysteresis (CtrnHysteresis)
- Counter Scalar (CtrnScalar)
- Cyclic Rate Update Time (CtrnCyclicRateUpdateTime)
- Configuration Flags
- Range High Limit (Range0To11[n].HighLimit) and Range Low Limit (Range0To11[n].LowLimit)
- Range Output Control (Range0To11[n].OutputControl)
- Range Configuration Flags
- Output Array
- Output on Mask (OutputOnMask.0 through OutputOnMask.15)
- Output Off Mask (OutputOffMask.0 through OutputOffMask.15)
- Range Enable (RangeEn.0 through RangeEn.15)
- RBF - Reset Blown Fuse (ResetBlownFuse)
- Control Bits
- Range High Limit or Direct Write Value (Range12To15[n].HiLimOrDirWr)
- Range Low Limit (Range12To15[n].LowLimit)
- Range Output Control (Range12To15[n].OutputControl)
- Range Configuration Flags (12To15)
- Input Array
- Input State (InputStateA0 through InputStateZ1)
- Readback (Readback.0 through Readback.15)
- Status Flags
- Range Active (RangeActive.0 through RangeActive.15)
- Current Count (Ctr[n].CurrentCount)
- Stored Count (Ctr[n].StoredCount)
- Current Rate (Ctr[0].CurrentRate to Ctr[3].CurrentRate)
- Pulse Interval (Ctr[0].PulseInterval and Ctr[1].PulseInterval)
- Status Flags
- 5 - Diagnostics and Troubleshooting
- A - Specifications
- B - Program a 1769-HSC Module, CompactLogix Controller, and 845F Incremental Encoder with RSLogix 5000 Software
- C - Program a 1769-HSC Module, MicroLogix 1500 Controller, and 845F Incremental Encoder with RSLogix 500 Software
- D - Programming Quick Reference
- E - History of Changes
- Glossary
- Index
- Back Cover

68 Rockwell Automation Publication 1769-UM006E-EN-P - July 2013
Chapter 4 Module Configuration, Output, and Input Data
35
Not used Lin-
ear
Not used Counter 2
Configuration Flags
36 Ctr3MaxCount Counter 3 Maximum
Count
37
38 Ctr3MinCount Counter 3 Minimum
Count
39
40 Ctr3Preset Counter 3 Preset
41
42 Ctr3Hysteresis Counter 3 Hysteresis
43 Ctr3Scalar Counter 3 Scalar
44 Ctr3CyclicRateUpdateTime Counter 3 Cyclic Rate
Update Time
45
Not used Lin-
ear
Not used Counter 3
Configuration Flags
46 Range0To11[0].HighLimit Range 0 High Limit
47
48 Range0To11[0].LowLimit Range 0 Low Limit
49
50 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 0 Output Control
51
Not used Inv Not used Type Not used ToThisCtr Range 0 Configuration
Flags
52 Range0To11[1].HighLimit Range 1 High Limit
53
54 Range0To11[1].LowLimit Range 1 Low Limit
55
56 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 1 Output Control
57
Not used Inv Not used Type Not used ToThisCtr Range 1 Configuration
Flags
58 Range0To11[2].HighLimit Range 2 High Limit
59
60 Range0To11[2].LowLimit Range 2 Low Limit
61
62 Out
15
Out
14
Out
13
Out
12
Out
11
Out
10
Out
09
Out
8
Out
7
Out
6
Out 5 Out 4 Out
3
Out 2 Out
1
Out
0
Range 2 Output Control
63
Not used Inv Not used Type Not used ToThisCtr Range 2 Configuration
Flags
64 Range0To11[3].HighLimit Range 3 High Limit
65
Table 12 - Configuration Array - 1769-HSC Module and CMX 5370 L2 Packaged Controller Embedded HSC (Continued)
Word
Bit
Function
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00