Table B.C
Diagnostic
Status Reply for KF3
Byte Description Status Reply (hex)
1 Mode/Status byte 00 (No Modes)
2 Interface/Processor Type
Bits 03: Interface type
(E = Extended)
Bits 47: Processor type
(F = Computer)
FE
3 Extended Interface Type 2C
4 Not Used
5 Series/Revision
Bits 04:
Bits 57:
0 = Revision A
1 = Revision B, etc.
0 = Series A
1 = Series B, etc.
616 Bulletin Name = (ASCII) 1770KF3"
1724 Productspecific Information 0
This command resets the diagnostic counters in the node interface module.
Figure B.7
Diagnostic
Counter Reset Command Format
CMD
06
STS TNS FNC
07
1
byte
1 byte
2 bytes
1 byte
Figure B.8
Diagnostic
Counter Reset Reply Format
CMD
46
STS TNS
1
byte
1 byte
2 bytes
Diagnostic Counter Reset