Installation Data Communication Interface Module Cat. No. 1784-KT2/C Communication Interface Module Cat. No.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Compatibility The 1784–KT2/C has been verified for operation with the following computers: Allen-Bradley 6123, 6124 IBM PS/2 7541, 7561, 8550, 8555, 8560, 8570, 8580 We will refer to the 1784–KT2/C Communication Interface Module as simply the 1784–KT2 throughout this document.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Allen-Bradley publication SGI–1.1 “Safety Guidelines for the Application, Installation and Maintenance of Solid State Control” (available from your local Allen-Bradley office) describes some important differences between solid–state equipment and electromechanical devices which should be taken into consideration when applying products such as those described in this publication.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C WARNING: This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C 2. Press the [Control], [Alt] and [Del] keys at the same time. 3. When you receive the following message, press [ENTER]. Press [ENTER) to continue. 4. The main menu appears: MAIN MENU 1. Learn about the computer 2. Backup the Reference Diskette 3. Set configuration 4. Set features 5. Copy an option diskette 6. Move the computer 7. Test the computer Use ↑ or ↓ to select. Press Enter.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C 2. Cycle the power switch. When the following message appears, press [ENTER]: Press [ENTER) to continue. 3. When the main menu appears move the cursor down to the Set Configuration option and press [ENTER]. MAIN MENU 1. Learn about the computer 2. Backup the Reference Diskette 3. Set configuration 4. Set features 5. Copy an option diskette 6. Move the computer 7. Test the computer Use ↑ or ↓ to select. Press Enter.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Installing the 1784-KT2 This section explains how to install the 1784–KT2 into an Allen-Bradley 6123 or 6124, or an IBM PS/2 computer. When installing the module into a 6123 or 6124, refer to the 6123/6124 User’s Manual (publication 6123–2.1) for additional considerations. Important: Read the IBM PS/2 Model Quick Reference guide before you install the 1784–KT2.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C You are now ready to configure your 1784–KT2. Refer to the next section. Configuring the 1784-KT2 Important: You need to prepare the PS/2 Reference diskette for 1784–KT2 configuration capability. If you have not yet done so, refer to the section earlier in this document. To configure the 1784–KT2, follow these steps: 1. Insert the IBM PS/2 Reference diskette into drive A. 2. Turn on the computer. 3.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Change Configuration Total System Memory Installed Memory . . 2048KB (2.0MB) Useable Memory . . 2048KB (2.0MB) Built In Features Installed Memory . . 2048KB (2.0MB) Diskette Drive A Type . . . . . . 1.44MB [3.5"] Diskette Drive B Type . . . . . . [Not Installed] Math Coprocessor . . . . . . . . . [Not Installed] Serial Port . . . . . . . . . . . . . . [Serial_1] Parallel Port . . . . .
Installation Data Communication Interface Module Cat. No. 1784-KT2/C 8. Set the interrupt level by moving the cursor down to the Interrupt Level option. Use [F5] and [F6] to scroll back and forth through the interrupts. Display your selection on the screen. Make sure you select an interrupt that is not being used by another adapter card in your PS/2 computer. The 1784–KT2 supports the following interrupts: IRQ9 IRQ10 IRQ11 IRQ12 If you are using a PLC–2 or PLC–3, continue with Step 9.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Table 1 Required Cables for Connecting to a Programmable Controller Use this cable: When connecting to: 1784-CP2 PLC-2 Family Programmable Controllers 1784-CP3 PLC-3 Family Programmable Controllers 1784-CP PLC-5 Family Programmable Controllers 1784-CP6 PLC-5/40 and PLC-5/60 Programmable Controllers (refer to publication 1784-2.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Figure 1 Cable Pinouts for the 1784- CP2 Cable Connecting the 1784-KT2 to a PLC-3 To connect the 1784–KT2 to a PLC–3, follow these steps: WARNING: To avoid personal injury, always disconnect the ac power before making the cable connection. 1. Plug the 62–pin connector end of the 1784–CP3 cable into the 1784–KT2 and secure with captive screws. 2.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Figure 2 Cable Pinouts for the 1784-CP3 Cable Connecting the 1784-KT2 to a PLC-5 To connect the 1784–KT2 to a PLC–5, follow these steps: WARNING: To avoid personal injury, always disconnect the ac power before making the cable connection. 1. Plug the 62–pin connector end of the 1784–CP cable into the 1784–KT2 and secure with captive screws. 2. Connect the other end of the 1784–CP cable into the PEER COMM INTFC connector on the PLC–5.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Important: To allow communication between PLC–5s and other Data Highway Plus nodes, you must connect your PS/2 to a PLC–5 using a 1784–CP cable. The Data Highway Plus network is connected to the PLC–5. Figure 3 shows cable pinouts for the 1784–CP cable.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C To properly execute the diagnostic program, you must have the following: an IBM PS/2 7541, 7561, 8550, 8555, 8560, 8570, or 8580 computer with the 1784–KT2 installed OR an Allen-Bradley 6123 or 6124 computer with the 1784–KT2 installed DOS V3.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C 2. When the prompt appears, type the following to select the hard disk: c: 3. [ENTER] When the prompt appears, type the following to select the top directory of the hard disk: cd c:\ 4. [ENTER] When the prompt appears, type the following to create a directory called KT: mkdir kt 5. [ENTER) When the prompt appears, type the following to create a directory called KT2DIAG: mkdir kt2diag [ENTER] 6.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C The following sections describe how to start the diagnostic program from the: backup copy of the Options and Diagnostics diskette OR hard disk You are not required to start the diagnostic program from both the backup copy of the Options and Diagnostics diskette and the hard disk. If you plan to start the diagnostic program from the hard disk, turn to the section “Starting Up from a Hard Disk” later in this document.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Important: The diagnostic program adds new test results to results already existing in the output file. If you want to delete test results already existing in the output file, wait for the prompt to appear and type: del kt2out.txt [ENTER) Do this before you proceed to step 4. 4.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C When the prompt appears, type: cd c:\kt2diag [ENTER) Important: The diagnostic program adds new test results to results already existing in the output file. If you want to delete test results already existing in the output file, wait for the prompt to appear and type: del kt2out.txt [ENTER] Do this before you proceed to step 3. 3.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Running the Diagnostic Program When you have completed the start–up procedures, the following screen appears: You must now specify which 1784–KT2 module you want to test. To do this, follow the steps below: 1. Press [F3]. The number of each slot containing a 1784–KT2 is displayed. 2. Specify the slot number of the 1784–KT2 you want to test by moving the cursor to the desired slot number and pressing [ENTER].
Installation Data Communication Interface Module Cat. No. 1784-KT2/C The Host Diagnostics Test The Host Diagnostics option allows you to test for proper communication between the PS/2 computer and the 1784–KT2. To perform this test, follow the steps below: 1. Place your cursor on the Host option and press [ENTER]. 2. You are asked if you want to run a single test (Single Pass) or a specified number of tests (Repeat). Place your cursor on Single Pass or on Repeat and press [ENTER].
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Table 2 Host Diagnostics Screen Definitions This term: Indicates: Configuration the 1784-KT2's configuration parameters. Memory Address the 1784-KT2's configured memory address. Interrupt Level the 1784-KT2's configured interrupt level. Mode Selection the 1784-KT2's configured auxiliary communication port. Adapter ID the 1784-KT2's adapter identification number (60C6).
Installation Data Communication Interface Module Cat. No. 1784-KT2/C After you make your selection, the following screen appears: Table 3 describes each of the above terms. Table 3 Card Diagnostics Screen Definitions This term: Indicates: Start/Stop 1784-KT2 Processor (Z80 CPU) tests results of the PS/2's ability to perform a software reset of the 1784-KT2. After the reset, the 1784-KT2's status and execution capabilities are verified.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C The Card Diagnostics test runs according to the number of times specified in step two. Your screen shows you when the tests are complete (Status column), how many errors were discovered (Failures column), and final test results (Results column). 3. When you are finished, press any key to return to the main menu.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C If you choose Repeat, you are asked how many passes you want to make. Specify this number and press [ENTER]. After you make your selection, the following screen appears (in this example, the PLC–2 function is displayed): Table 4 describes each of the above terms. Table 4 Off-line Communications Diagnostics Screen Definitions This term: Indicates: DH+ test results of the loopback test.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C The All Components Diagnostic Test The All Components option allows you to run the Host, Card, and Off–line Communications tests discussed in the previous sections. To perform an All Components test, follow these steps: 1. Install your PLC–2 or PLC–3 loopback connector. 2. Place your cursor on the All Components option and press [F4]. 3. Follow steps 3 through 8 of the Off–line Communications test.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C This error message: Indicates: 48-56 Diagnostic Time outs the 1784-KT2 cannot be started or stopped, or the 1784-KT2 is configured at an address already in use, or a dual port memory error has occurred, either on the 1784-KT2 side or the PS/2 side, preventing download or execution of the test.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Figure 4 The Output File For a Card Diagnostics Test CARD DIAGNOSTICS PASS: 1 OF 2 Start/Stop 1784-KT2 Proce . . . Error: No error found. NUM FAILS: 0 PASS/FAIL: PASS Dual Port (KT2 side) . . . . . . . . Error: No error found. NUM FAILS: 0 PASS/FAIL: PASS Interrupts (PS2 to KT2) . . . . . . Error: No error found. NUM FAILS: 0 PASS/FAIL: PASS Memory . . . . . . . . . . . . . . . . . Error Code: 128 RAM1 Failure.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Building Loopback Connectors This section shows you how to build the PLC–2 and PLC–3 loopback connectors required for Off–Line Communications Diagnostics tests. Two loopback tests are performed during an Off–Line Communications test.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C 30 4. Insert 5 of the wires into the back of a connector housing according to the following PLC–2 wire–assembly diagram. Label this connector PLC–2. 5. Insert 3 of the wires into the back of the remaining connector housing according to the PLC–3 wire–assembly diagram shown below. Label this connector PLC–3.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C Specifications Specifications for the 1784–KT2 are listed below. Module Location IBM PS/2 computer, 8/16-bit MicroChannel slot Module Output Connector 62-pin D-shell Outputs PLC-2 serial interface PLC-3 serial interface Data Highway Plus Module Compatibility Allen Bradley 6123 Allen Bradley 6124 IBM PS/2 Hardware Interrupt IRQ9 IRQ10 IRQ11 IRQ12 Baud Rate Asynchronous (PLC-2, PLC-3): 9600; 19.
Installation Data Communication Interface Module Cat. No. 1784-KT2/C With offices in major cities worldwide WORLD HEADQUARTERS Allen-Bradley 1201 South Second Street Milwaukee, WI 53204 USA Tel: (1) 414 382-2000 Telex: 43 11 016 FAX: (1) 414 382-4444 EUROPE/MIDDLE EAST/AFRICA HEADQUARTERS Allen-Bradley Europe B.V. Amsterdamseweg 15 1422 AC Uithoorn The Netherlands Tel: (31) 2975/43500 Telex: (844) 18042 FAX: (31) 2975/60222 Publication 1784–6.5.