Installation Instrucitons Owner manual

Use IOView to Verify the Configuration 6-13
Publication 1784-IN042A-EN-P - April 2005
2. Create either a Network view or an I/O Set view.
T
o create a Network view, select Edit Create Network View.
T
o create an I/O Set view, select Edit Create I/O Set View.
You see this screen:
3. Select OK to
create the view.
In This Field Do This
Port Number Verify the Port Number corresponds to the 1784-PKTCS card for which you
w
ant to create the view
Read/Write Period (ms) Select the Read/Write Period (in milliseconds)
Privilege Select whether the view is Read-Only or Read/Write
Watchdog
Set the card-to-driver watchdog timeout (in milliseconds)
TIP
Input data from a connection can be contained in multiple views. Output
data for a connection can be contained only in one view which has
Read/Write privileges.