Installation Instructions User guide
Table Of Contents
- 1794-IN108D-EN-P FLEX I/O 8 Input HART Analog Module Installation Instructions
- Back Cover

FLEX I/O 8 Input HART Analog Module 25
Publication
1794-IN108D-EN-P - January 2014
Remote Transmitter Error Up/Down (Series A Mode)
Word 0 Bit 08 Up/down for Channels 0...3
Word 1 Bit 08 Up/down for Channels 4...7
Where: O = up
1 = down
Data Format (Series A Mode)
Word
Bits
D
escription
0 04 03 02 01 Channels 0...3
1 04 03 02 01 Channels 4...7
00000…22 mA = 0...22,000 with error steps (default)
00010…22 mA = 0…110%, with error steps
00100…22 mA = 0…104.8%, square root, with error steps
00110…20 mA = 0…65,535, unsigned integer, with error steps
01002…22 mA, with error steps
01012…22 mA = -12.5%…112.5%, with error steps
01104…22 mA = 0…106%, square root, with error steps
01114…20 mA = 0…65,535, unsigned integer, with error steps
1000Not assigned
1001Not assigned
1010Not assigned
10110…22 mA = A/D count, with fixed error
11003.6…21 mA = NAMUR NE 43, with fixed error
11013…21 mA = -6.25 to 106.25% with fixed error
11102…22 mA = -12.5 to 112.5% with fixed error
1111Not assigned