Crane Setup - Encoderless
These setup instructions assume the following.
Drive and motor size have been carefully selected
External braking resistor has been properly sized
The drive is at factory defaults.
If not, unplug the output relay terminal block and issue a reset to factory
defaults for the HOST and all PORTS. Plug terminal block back in.
Programming is done via DriveExecutive or DriveExplorer
Crane control is done via Run forward / Run Reverse inputs
Mechanical brake control is wired to Output Relay 0
ATTENTION: Loss of control in suspended load applications can cause personal
injury and/or equipment damage. The drive or a mechanical brake must always
control the loads. Parameters 1100…1113 are designed for lifting/torque
proving applications. It is the responsibility of the engineer and/or end user to
configure drive parameters, test any lifting functionality and meet safety
requirements in accordance with all applicable codes and standards.