22-COMM-B_10_4.qxd:Layout 1 10/4/06 1:08 PM Page 1 PRODUCT PROFILE 22-COMM-B BACnet® MS/TP ADAPTER The PowerFlex® 22-COMM-B adapter provides an internal BACnet MS/TP connection to PowerFlex 40 and 400 drives. It can also be installed in a DSI External Communications Kit for use with PowerFlex 4 drives. The adapter provides a means to control, configure, and collect data over a BACnet MS/TP network.
22-COMM-B_10_4.qxd:Layout 1 10/4/06 1:08 PM Page 2 PARAMETERS SPECIFICATIONS No. 01 02 Communications 03 04 05 06 07 08 09 10 11 12 Name Description Reset Module Resets the adapter or sets the adapter parameters to factory default. Comm Loss Action Sets the action that the adapter and drive will take if the adapter detects a network failure. Comm Loss Time Sets the communication loss timeout period (in seconds).
22comm_C_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 12:53 PM Page 1 PRODUCT PROFILE 22-COMM-C ControlNet™ ADAPTER The PowerFlex® DSI ControlNet adapter provides redundant coaxial ControlNet connections for PowerFlex 40 or PowerFlex 400 drives. The adapter provides a means to control, configure, and collect data over a ControlNet network.
22comm_C_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 PARAMETERS Description 01 Mode Displays the Single or Multi-Drive operating mode selected with the Operating Mode Jumper (J7) on the adapter. 02 CN Addr Cfg Sets the ControlNet node address if the Node Address Switches are set to “00”. (Updates Parameter 03 - [CN Addr Act] after a reset.) 03 CN Addr Act Displays the ControlNet node address actually used by the adapter.
22comm_D_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/25/06 12:06 PM Page 1 PRODUCT PROFILE 22-COMM-D DeviceNet™ ADAPTER The PowerFlex® 22-COMM-D adapter provides a DeviceNet network connection for PowerFlex 40 AC drives and other DSI-based host devices with an internal communications slot. The adapter provides a means to control, configure and collect data over a DeviceNet network.
22comm_D_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/25/06 12:06 PM Page 2 PARAMETERS SPECIFICATIONS No. Name Description Communications 01 Mode Displays the mode selected by the jumper on the adapter (Single or Multi-Drive). 02 DN Addr Cfg Sets the DeviceNet node address after a reset or power cycle. 03 DN Addr Act Displays the DeviceNet node address currently used by the adapter. 04 DN Rate Cfg Sets the DeviceNet data rate after a reset or power cycle.
22comm_E_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 1:52 PM Page 1 PRODUCT PROFILE 22-COMM-E EtherNet/IP™ ADAPTER The PowerFlex® 22-COMM-E adapter provides an EtherNet/IP network connection for PowerFlex 40 AC drives and other DSI-based host devices with an internal communications slot. The adapter provides a means to control, configure and collect data over an EtherNet/IP network.
22comm_E_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 PARAMETERS No. Name Description 01 Mode Displays the mode selected by the jumper on the adapter (Single or Multi-Drive). 02 BOOTP Sets the DeviceNet node address after a reset or power cycle. 03 IP Addr Cfg 1 04 IP Addr Cfg 2 Sets the respective bytes in the IP address, where the represented address is: Cfg1.Cfg2.Cfg3.Cfg4.
22comm_E_PP_NL_8_23.qxd:Product_app_profile5-18-05.
22comm_E_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd Publication 22COMM-PP001D-EN-P – July 2006 Supersedes Publication 22COMM-PP001C-EN-P – December 2005 8/23/06 1:52 PM Page 4 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
PRODUCT PROFILE 22-COMM-L LonWorks® ADAPTER The PowerFlex® DSI LonWorks™ adapter provides an internal LonWorks connection for PowerFlex 40 and PowerFlex 400 drives. It can also be used with other Allen-Bradley products that support a DSI adapter, such as the DSI External Communications Kit (22-XCOMMDC-BASE) which enables PowerFlex 4 drives to connect to a LonWorks network. (PowerFlex 4 drives cannot support an internally-mounted adapter.
PARAMETERS SPECIFICATIONS No. Name Description Communications 01 Send Service Pin Broadcasts a LON Service Pin message from the Neuron Chip to provide the Neuron ID. 02 Neuron State Displays the state of the Neuron Chip 03 Reset Module Resets the adapter or sets the adapter parameters to factory default. 04 Neuron ID Displays the Neuron Chip ID. 05 Clear Counters Clears the network diagnostic counters.
22comm_P_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 2:55 PM Page 1 PRODUCT PROFILE 22-COMM-P PROFIBUS DP™ ADAPTER The PowerFlex® 22-COMM-P adapter provides a PROFIBUS DP network connection for PowerFlex 40 and 400 AC drives and other DSI-based host devices with an internal communications slot. The adapter provides a means to control, configure and collect data over a PROFIBUS DP network.
22comm_P_PP_NL_8_23.qxd:Product_app_profile5-18-05.qxd 8/23/06 2:55 PM Page 2 PARAMETERS SPECIFICATIONS No. Name Description Communications 01 Mode Displays the mode selected by the J2 jumper (Single or Multi-Drive). 02 Reserved 03 Reserved 04 P-DP Addr Actual Displays the node address actually used by the adapter. 05 P-DP Rate Actual Displays the data rate actually used by the adapter. 06 Reserved 07 Reserved 08 Reset Module Used to reset the adapter or set defaults.
22-SCM-232_PP_9_28.qxd:Product_app_profile5-18-05.qxd 9/28/06 7:37 AM Page 1 PRODUCT PROFILE 22-SCM-232 RS-232 DF1™ MODULE The PowerFlex® 22-SCM-232 provides an RS-232 DF1 connection for PowerFlex 4 and 40 AC drives and other DSI-based host devices. The module provides a means for drive software tools, such as DriveExplorer™ and DriveExecutive™, to communicate with drive products.
22-SCM-232_PP_11_1.qxd:Product_app_profile5-18-05.qxd 11/1/06 11:31 AM Page 2 PARAMETERS SPECIFICATIONS No. Name Description Communications 01 Sets the operation of the serial converter (Auto, Master, Slave, RTU Master, and RTU Pass-thru). Adapter Cfg 02 DF1 Addr Cfg Configures the DF1 address used for the serial converter. 03 DF1 Rate Cfg Configures the data rate used for the serial port.
1769-SM2_PP_NL_9_28.qxd:Product_app_profile5-18-05.qxd 9/28/06 7:39 AM Page 1 PRODUCT PROFILE 1769-SM2 COMPACT I/O™ MODULE The 1769-SM2 module provides a direct 1769 platform connection for PowerFlex® 4, 40, and 400 AC drives, other DSI-based host devices, and Modbus RTU-based host devices such as PowerFlex 70, 700, and 700S AC drives equipped with 20COMM-H adapters.
1769-SM2_PP_NL_9_28.qxd:Product_app_profile5-18-05.qxd 9/28/06 PARAMETERS No. Name Description 01 Config Mode Displays the module’s configuration mode. 02 DSI Mode Displays the module’s operating mode (single or multi-drive). 03 Reset Module Used to reset the module or set defaults. 04 Idle Action 1 Sets the action that the module and CH1 drive take if the module detects that the controller was switched to Program mode or Test mode.
1769-SM2_PP_NL_10_4.qxd:Product_app_profile5-18-05.qxd 10/4/06 1:10 PM Page 3 EXAMPLE SYSTEMS RUN RUN PORT MOD NET A NET B 0.00 Hz 2.5 Cans/Sec 646.0 Bus/Volt STS RUN RUN PORT MOD NET A NET B 0.00 Hz 2.5 Cans/Sec 646.
1769-SM2_PP_NL_9_28.qxd:Product_app_profile5-18-05.qxd Publication 22COMM-PP001D-EN-P – July 2006 Supersedes Publication 22COMM-PP001C-EN-P – December 2005 9/28/06 7:39 AM Page 4 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
22comm_Xdcbase_PP_NL_9_28.qxd:Product_app_profile5-18-05.qxd 9/28/06 7:41 AM Page 1 PRODUCT PROFILE DSI EXTERNAL COMMUNICATIONS KIT The DSI External Communications Kit (22-XCOMM-DC-BASE) provides a network connection for PowerFlex® 4, 40, and 400 AC drives. Each kit can serve up to 5 drives via their RS-485 ports. Communications PRODUCT HIGHLIGHTS Multiple Network Connectivity – Provides a network connection for DSI-based PowerFlex 4, 40, and 400 AC drives.
22comm_Xdcbase_PP_NL_9_28.qxd:Product_app_profile5-18-05.qxd 9/28/06 7:41 AM Page 2 SPECIFICATIONS Communications Network Drive Protocol Dependent on installed adapter Data Rate Dependent on installed adapter Protocol Data Rate Electrical Consumption Network DSI 19.
DSI WIM_22Comm PP_9_28:Layout 1 9/28/06 7:54 AM Page 1 PRODUCT PROFILE DSI WIRELESS INTERFACE MODULE The DSI Wireless Interface Module (WIM) provides a wireless communication interface between a Pocket PC, laptop computer or desktop computer equipped with Bluetooth® wireless technology, and any Allen-Bradley® product supporting the DSI™ protocol. Connectivity includes the entire PowerFlex® 4-Class Family of drives and peripherals.
DSI WIM_22Comm PP_10_4:Layout 1 11/1/06 9:53 AM Page 2 PARAMETERS SPECIFICATIONS No. 01 02 03 Radio 04 05 06 07 08 09 10 11 Name Adapter Cfg Adapter Type Drive Addr Cfg Description Sets the operating mode of the WIM. Displays the present operating mode of the WIM. Sets the node address of the WIM for use with the WIM operating mode set with Parameter 01 - [Adapter Cfg].
1203-USB_9_28.qxd:Layout 1 9/28/06 7:56 AM Page 1 PRODUCT PROFILE 1203-USB UNIVERSAL SERIAL BUS™ CONVERTER The 1203-USB Converter provides direct USB connectivity to PowerFlex® 70 (SC or EC), 700 (SC or VC), 700H and 700S drives, PowerFlex 4, 40, 40P and 400 drives, and other DPIbased or DSI-based host devices all-in-one product (combines 1203-SSS & 22-SCM-232 technology). It can also be used with legacy SCANport-based host devices such as Bulletin 1336 PLUS II and 1305 drives.
1203-USB_9_28.qxd:Layout 1 9/28/06 7:56 AM Page 2 PARAMETERS (DPI MODE) PARAMETERS (SCANport MODE) No. 01 02 03 No. 01 02 03 04 05 06 07 08 09 Name DPI Port Reset Module Clear DF1 Counts Description Displays the port on the host drive which the converter is connected. Resets the converter or sets the converter parameters to factory default. Resets the DF1 statistical Parameter 04 - [DF1 Packets Sent] and Parameter 05 - [DF1 Packets Rcvd] to 0 if set to “1 = Clear Counts”.
22Comm Cover_NL_11_1.qxd:Layout 1 11/1/06 9:51 AM Page 3 4-CLASS CONNECTIVITY PowerFlex 4-Class Communication Adapter / Module Protocol 4 40 400 (internal) Modbus RTU std. std. std.
22Comm Cover_NL_11_1.qxd:Layout 1 11/1/06 9:47 AM Page 4 PowerFlex is a registered trademark of Rockwell Automation. DriveExplorer, DPI, DriveExecutive, Remote I/O, and Compact I/O are trademarks of Rockwell Automation. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 22COMM-PP001D-EN-P – July 2006 Supersedes Publication 22COMM-PP001C-EN-P – December 2005 Copyright ©2006 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.