Manual

Tool Control Functions
Chapter 20
2
0
-
1
8
Figure 20.3
Typical Tool Group Data Screen
CHANGE
TOOL
INSERT
TOOL
DELETE
TOOL
CHANGE
TYPE
CHANGE
T RATE
ENTER DATA:
EDIT TOOL GROUP 1 PAGE 1 OF 1
(FILE NAME) THRESHOLD RATE =80%
ENTRY TOOL NUMBER LIFE TYPE = TIME
NO OFF NO
1 2
2 4
3 6
4 8
5. From this screen, you can:
Operation: Description:
Change tools Alter oneof the toolnumbers that hasalready been entered in the group. Move thecursor to thetool number tobe changed
by pressingthe upor downcursor keys (movethe cursor fullpages byholding downthe shift keywhile pressinga cursor
key). Press the {CHANGETOOL}softkey. Key in the new toolnumber andpress the [TRANSMIT] key.
Insert tools Insert a newtool number for that group. Move thecursor tothe locationto insert anew tool numberat by pressingthe upor
down cursor keys (move the cursor fullpages byholding downthe shift keywhile pressinga cursor key). Press the
{INSERTTOOL}softkey. Key in the new toolnumber andpress the [TRANSMIT] key. The actualrange of allowabletool
numbers is1 to9999.
Delete tool Remove atool number from that group. Move thecursor to the tool numberto beremoved by pressing theup ordown
cursor keys(move thecursor full pagesby holdingdown theshift key whilepressing acursor key). Press the{DELETE
TOOL}softkey. Respond yesor no andpress [TRANSMIT].
Change life type Alter how the control records andmeasures toollife for that group. Press the {CHANGETYPE} softkey. The prompt LIFE
TYPE... is displayed online 2of the CRT. The samelife typeis assignedto all toolsin any one toolgroup. Key in the
number of thedesired toollife measurement typefor that group and press the[TRANSMIT] key. 0 for time,1 for number of
tool uses,and 2for distance.
Change life threshold rate Alter the percentageof a tools expectedlife sothat a toolis labeledas old. This percentageapplies to all tools inthe
selected group. To alter thethreshold percentage(the percentageof total toollife that hasbeen usedbefore atool willbe
classified as old) press the{CHANGE TRATE} softkey. Key in thepercentage of the total tools lifeso that thetool is
classified as old andpress the[TRANSMIT] key. Tool life thresholdrate isexplained earlierin this section.
Change Color
(softkey level 4)
EDT LN
OF #
EDT CT
COMP #
EDIT
LIFE
RENEW
TOOL
SCROLL
COLOR
The application of these operations was described in detail earlier in this
section. All of this information can be entered into the tool groups using
the programming method described on page 20-22 .