Manual

OffsetTable and Setup
Chapter 3
3-13
Your system installer initially sets these values in AMP. You can modify
them with online AMP by using this screen:
Per tablevalues
Per axisvalues
softkey level5
About the Offset Range Verification Screen
on a lathe, range checking units for this screen are always RADIUS,
regardless of the program/control mode
display format is fixed
Mode Places to the left of the decimal point Places to the right of thedecimal point
inch 3 5
metric 4 5
data entry is bounded by the programming resolution of the axes
When Does Verification Occur?
Verification occurs when a value enters the table from:
· data entry screens · PAL · paramacros
Important: The control does not perform the verification if the value,
old or new, is zero, nor does it check G10 data-setting
codes.