APS Import/Export Utility User Manual
5-24
Notice in the preceding example that “0XE000” indicates that control bits EN, TT
and DN are set to one.
Enter the contRol (R) data values in the following order: CTL, LEN and POS. The
import utility does not prevent undefined control bits from being set. Providing data
for undefined control bits does not affect a program.
The control word (CTL) defines the control bits for timers (T), counters (C) and
control (R) file. See tables 5.S, T
, and U.
Table 5.S
Control Bits for Timers Defined by the Word CTL
Bit Address Bit Name Bit Number
T4:0/EN Enable 15
T4:0/TT Timing 14
T4:0/DN Done 13
Table 5.T
Control Bits for Counters Defined by the Word CTL
Bit Address Bit Name Bit Number
C5:0/CU Counter up enable 15
C5:0/CD Counter down enable 14
C5:0/DN Done; accumulator w preset value 13
C5:0/OV Overflow 12
C5:0/UN Underflow 11
C5:0/UA Update accumulator (HSC only) 10
C5:0/HP Accumulator w hi preset (MicroLogix 1000 controller HSC only) 9
C5:0/LP Accumulator v lo preset (MicroLogix 1000 controller HSC only) 8
C5:0/IV Overflow interrupt (MicroLogix 1000 controller HSC only) 7
C5:0/IN Underflow interrupt (MicroLogix 1000 controller HSC only) 6
C5:0/IH Hi preset interrupt (MicroLogix 1000 controller HSC only) 5
C5:0/IL Lo preset interrupt (MicroLogix 1000 controller HSC only) 4
C5:0/PE User interrupt pending (MicroLogix 1000 controller HSC only) 3
C5:0/LS User interrupt is lost (MicroLogix 1000 controller HSC only) 2
C5:0/IE Interrupt enable (MicroLogix 1000 controller HSC only) 1