User Manual


 !     
 
 
    
 
 
14C223 Voltage/Tachometer Follower Enables drive to follow a reference source that is indeĆ
pendently generated.
DĆ3971
14C224 Torque Taper Allows adjustment of slope and break point of drive
speed - torque curves - increases current limit with
speed, i.e. center window.
-
14C225 Test Meter Adapter Provides a safe and convenient means to measure and
monitor drive regulator analog signals.
DĆ3970
14C226 Automatic Reversing Enables automatic reversal of the armature loop conĆ
tactors. (requires the drive to be equipped with a reĆ
versing contactor.) In this mode, the motor's energy is
returned to the AĆC line [inverting]. This kit is intended
for very infrequent
automatic reversal. If the second
quadrant mode [inverting] is frequently used, an invertĆ
ing fault circuit breaker should be added.
-
14C230 Dancer Follower Enables automatic control of the drive by a line speed
signal, trimmed by a dancer roll potentiometer.
DĆ3966
14C232 Major Loop Tuning Allows the User to change the proportional and integral
gain of the major loop.
14C233 Dancer Position Regulator Provides a center seeking position regulator for dancer
controlled applications.
D2Ć3207
14C237 Shunt Field Supply Provides a full wave field excitation for shunt wound
DĆC motors. 3 amp capacity included on all drives 2
HP and higher.
-
14C276 M" Contactor Adapter Provides the interconnecting cable to connect the conĆ
tactor into the regulator sequencing circuit when the
Basic Controller is used.
-
14C293 Contactor Reversing Second armature contactor and connecting control
cable to convert unidirectional drive into reversing
drive.
D2Ć3293
9C200 Operator's Station Standard NEMA 4 control station; Start Pushbutton
Stop Pushbutton
Run/Jog Switch
Speed Setting Pot
-
9C300 Operator's Station Standard NEMA 4 control station; Start Pushbutton
Stop Pushbutton
Run/Jog Switch
Forward/Reverse Switch
Speed Setting Pot
-
9C42 Speed Potentiometer 2 watt, 5K ohm
potentiometer with knob for separate mounting.
-
9C43 Speed Rheostat 4 inch, 5K ohm rheostat with large knob for separate
mounting.
-
9C47 Remote Tork Limit Potentiometer Remote control of tork limit 10K ohm potentiometer for
separate mounting.
-
9C50 Speed Rheostat with LV1 4 inch, 5K ohm rheostat with large knob for separate
mounting, low voltage interlock.
-
9C55 Automatic - Manual Selector
Switch
Selects Auto/Manual mode of reference source for sepĆ
arate mounting.
-