User Manual

2:4
Table 2Ć2. Isolation Transformer Specifications.
HP
kVA Primary Vac
Secondary
Vac
Reliance Part
Number
1/4 0.5 230/460 115 77530Ć16A
0.5 575 115 77530Ć17A
1/3 0.75 230/460 115 77530Ć16B
0.75 575 115 77530Ć17B
1/2Ć3/4 1.5 115 115 77530Ć15D
230/460 115 77530Ć16D
575 115 77530Ć17D
230/460 230 77530Ć16D
575 230 77530Ć17D
1 2.0 230/460 230 77530Ć16E
575 230 77530Ć17E
1Ć1 1/2 3.0 230/460 230 77530Ć16F
575 230 77530Ć17F
2 5.0 230/460 230 77530Ć16G
575 230 77530Ć17G
3Ć5 10.0 230/460 230 77530Ć16H
575 230 77530Ć17H
NOTE: ! !%" #!$          '  $" &# !# #  #!"  #" !%
" ! "$  &#$# (  "$ '
Table 2Ć3. Fuse Requirements.
Dual Element Class
K5, RK5, 250VAC Fuse
HP
AĆC Line
Volts
Quantity AMP
Reliance Part
Number
1/4Ć3/4 115 1
1
15 64676Ć1W
1/2Ć1 1/2 230 2 15 64676Ć1W
2Ć3 230 2 30 64676Ć1Z
5 230 2 50 64676Ć1AD
1
Install fuse in input line L1 (hot line).
Table 2Ć4. Controller Modification Kits.
Kit Model
Number
Kit Name Functional Description
Instruction
Manual
14C214 Dynamic Braking Resistor
1/4 to 1/2 HP @115 VAC
2.0 to 3.0 HP @230 VAC
Dynamic braking resistor for reduced stopping time. -
14C215 3/4 HP @115 VAC
-
14C216 1/2 to 1 1/2 HP @230 VAC
5 HP @230 VAC
-
14C219
(B/M 54379Ć1)
Auxiliary M" Contactor Provides isolated Form C contact status of Drive M"
Contactor.
-
14C221 Tachometer Feedback Interfaces between the tachometer and the regulator
when speed regulations is desired.
DĆ3969
14C222 Instrument Interface/Preset
Speed Reference
Allows drive to follow an instrument signal of 0Ć5, 1Ć5,
4Ć20 or 10Ć50 miiliamp signal. Can also be used for
drive preset speed reference.
DĆ3967