User guide
EtherNet I/P Objects
C-3
Class Attributes
Instance Attributes
Services
Attribute
ID
Access
Rule Name Data Type Description
1 Get Revision UINT 1
2 Get Max Instance UINT Total number of instances
6 Get Max ID Number
of Class
Attributes
UINT 7
7 Get Max ID Number
of Instance
Attributes
UINT 100
Attribute
ID
Access
Rule Name Data Type Description
1 Get Vendor ID UINT 5 = Reliance Electric
2 Get Device Type UINT 127
3 Get Product Code UINT Number identifying product
name and rating
4 Get Revision:
Major
Minor
STRUCT of:
USINT
USINT
Value varies
Value varies
5 Get Status WORD Bit 0 = Owned
Bit 2 = Configured
Bit 10 = Recoverable fault
Bit 11 = Unrecoverable fault
6 Get Serial Number UDINT Unique 32-bit number
7 Get Product Name SHORT_STRING Product name and rating
9 Get Configuration
Consistency
Value
UINT CRC or checksum representing
the configuration of the product
100 Get NVS Info STRUCT of:
UDINT
SHORT_STRING
Product name and rating
Service Code
Implemented for:
Service NameClass Instance
0x01 Yes Yes Get_Attribute_All
0x05 No Yes Reset
0x0E Yes Yes Get_Attribute_Single