Installation manual

Publication 1747-RM001G-EN-P - November 2008
SLC Communication Channels 13-45
Importing User Provided Page Files to the SLC 5/05 Processor
Use RSLogix 500 to import user page files to the SLC 5/05 ASCII files:
1. In the Project folder (under the Data Files folder), right-click on the first
of the block of four consecutive ASCII files where you will import the
user page HTML file.
2. Click on Properties.
3. Click on Import HTML.
4. Use the browser to locate the user page HTML file you want to import.
5. Double-click on the file to select it.
6. Click OK.
7. Repeat this process for each desired user page file.
8. When all user page files have been imported, go online with your SLC
5/05 processor.
9. Select the User Provided Pages link to view the User Provided Pages
menu, as shown in the following example.
%format Legal values are %b for binary, %d for decimal, %0 for
octal and %x for hexadecimal. The following file types
allow the format to be specified.
Input
Output
Status
Integer
All other file types are displayed in an appropriate format.
If a %format modifier is present, the format may be
changed by clicking on the file type/number via a web
browser.
#expand Legal values are #c and #e. This modifier determines
whether the structure file types are displayed in their
expanded or compact formats. If a # modifier is present, the
format may be changed by clicking on the [+]/[-] via a web
browser. If a #modifier is not present, the default display of
expanded is used.
!comment Data after the exclamation point and up to the closing > is
displayed in the Comment column of the monitor.
Fixed display formats Float files are always output in floating point format
(“C”%g format). String files are always output as a null
terminated text string. Binary files are always output as
four binary nibbles. ASCII files are displayed in a memory
dump format.
Tag Item Description