Installation manual
Publication 1747-RM001G-EN-P - November 2008
D-14 Programming Instruction References
MSG
(5/05 Ethernet)
Message type 64=peer-to-peer
read/write 0=read, 1=write
target device 2=500CPU,
4=485CIF, 8=PLC5
local 16=local
control block direct N none
control block
length
51
(93 if logical ASCII
addressing is
used)
channel number 1 (Ethernet)
target node,
remote bridge link
ID, local and
remote bridge
node address
not applicable
IP address
(ww.xx.yy.zz)
any legal IP
address
local file address direct O, I, S, B, T, C, R, N,
F, A, ST, M
none
target file address direct O, I, S, B, T, C, R, N,
F, A, ST, M
0 to 255
message timeout 0 to 255
(1)
Supported only by SLC 5/03 (OS301 and higher), SLC 5/04, and SLC 5/05 processors.
(2)
Supported only by SLC 5/03 (OS302), and SLC 5/04 (OS401), and SLC 5/05 processors.
(3)
Not supported by SLC 5/01 processors and Fixed controllers.
(4)
Indexed addressing is not allowed when using T, C, R, or M addresses.
(5)
Supported only by L20, L30, and L40 Fixed SLC processors with DC inputs.
(6)
Supported only by SLC 5/02, SLC 5/03, SLC 5/04, and SLC 5/05 processors.
(7)
SLC 5/05 Channel 0 (RS-232 serial port) only.
(8)
For SLC 5/05, control block length = 55 if logical ASCII addressing is used.
(9)
File types F, A, and ST only apply to SLC 5/03 (OS301 or later), SLC 5/04, and SLC 5/05 processors.
Table D.3 Available Addressing Modes (Continued)
Instruction Description Instruction
Parameter
Valid Addressing
Mode(s)
Valid File Types Immediate
Values