COMPONENT MAINTENANCE MANUAL with IPL
TDR-94, PART NO 622-9352
STEP PROCEDURE DESIRED RESULTS
0.2 AUTOMATIC TEST EQUIPMENT (FINAL) TESTS
Preferred Setup: The TDR-94 and TDR-94D are
“semi-automatically” tested on a station configured per Figure
1001/GRAPHIC 34-50-96-99B-020-A01 and Table 9002/Table
34-50- 96-99A-032-A01. Test software is listed in Table
9002/Table 34-50-96-99A-032-A01. Insert Disk 1 and run
SETUP procedure.
Alternate Setup: The TDR-94 and TDR-94D are
"semi-automatically" tested on a station configured per Figure
1002/GRAPHIC 34-50-96-99B-036-A01and Table 9003/Table
34-50- 96-99A-042-A01. Test software is listed in Table
9003/Table 34-50-96-99A-042-A01. Insert Disk 1 and run
SETUP procedure.
N
OTE: Software is written/used by the factory, and may
contain specifications which are actually tighter than
required per the performance test requirements
(ptr). Therefore, refer to this test document for test
specifications for those automatic tests which fail.
0.3 IFR S-1403DL SETUP INFORMATION
The IFR S-1403DL test set must have C-Menu setup information
stored into memory for proper operation. Ensure that all
S-Menus (including S-Menu 00) are turned off. Set the following
C-Menu configuration and save it to store locations 1 and 2.
C-10 "f01 ATC" ANT B "off"
C-50 Counts "10s"
C-71 Trig Source "Selfinterr"
C-72 All On, Cal
C-73 All On
C-74 All On
C-75 ANT A mod source: "Int", ANT A Enable: "On"
C-76 S menu Radix: Octal
0.4 TES T CONDITIONS
Final data is to be taken after a 30 minute warm-up with
primary power applied. Perform the setup instructions in Table
1002/Table 34-50-96-99A-010-A01 for standard switch settings
prior to running an automatic test.
Final Performance (Customer Acceptance) Test. Cont.
Table 1001/Table 34-50-96-99A-009-A01
34-50-96
Page 1010
May 18/06