STEP PROCEDURE DESIRED RESULTS
16.10A.1 Configuration Select S0 (P1-28)
a. Verify that Configuration Select S0 and S1 discrete inputs
P1-28 and P1-17 are in the open-cir cuit state to select
configuration 0.
b. Via FMS/IRS Input Data Bus, provide the transponder
with the appropriate label and data indicated in Figure
1016/GRAPHIC 34-50-96-99B-034-A01. Each data
parameter must be updated at least once per second.
c. Interrogate the transponder with the MODE-S interrogations
indicated in Figure 1016/GRAPHIC 34-50-96-99B-034-A01
to request BDS register 5,0.
d. Verify that the transponder responds properly with a DF=20
reply that has the "MB" field in Figure 1016/GRAPHIC
34-50-96-99B-034-A01.
e. Connect Configuration Select S0 discrete input P1-28 to
ground to select configuration 1.
f. Interrogate the transponder with the MODE-S interrogation
indicated in Figure 1016/GRAPHIC 34-50-96-99B-034-A01
to request BDS register 5,0.
g. Verify that the transponder responds properly with a
DF=20 reply that has the "MB" field indicated in Figure
1016/GRAPHIC 34-50-96-99B-034-A01.
h. Remove the ground from Configuration Select S0 discrete
input P1-28.
i. Remove ARINC label 335 from the FMS/IRS Data Input Bus.
16.10A.2 Configuration Select S1 (P1-17)
a. Connect Configuration Select S1 discrete input P1-17 to
ground to select configuration 2.
b. Verify that Altitude Select AS0 and AS1 discrete inputs P2-41
and P2-42 are in the open-circuit state.
c. Ensure that no GPS data is being applied to the transponder
via the GPS Input Data Bus.
d. Via the FMS/IRS Input Data Bus, provide the transponder
with the labels and data indicated in Figure 1017/GRAPHIC
34-50-96-99B-035-A01. Each data parameter must be
updated at least once per second.
Final Performance (Customer Acceptance) Test. Cont.
Table 1001/Table 34-50-96-99A-009-A01
34-50-96
Page 1047
May 18/06